Sign in

No products in the cart.

Mo-Fr 8am 6pm CT

Emerson Rosemount™ 2088 - Gauge and Absolute Pressure Transmitter

REQUEST PRICE
Do you need more information? Contact us
Overview
Description
Documents
Accessories
Applications

Features

  • Gauge and absolute pressure, ranges up to 10,000 psi (689 bar)
  • Reference accuracy ±0.075% of span, ±0.065% of span with high accuracy option P8
  • Rangeability of 50:1
  • 4-20 mA HART (Revision 5 or 7, selectable) or 1-5 Vdc HART Low Power output
  • Local Operator Interface (LOI) and configurable LCD display for process variable, percent of range, and diagnostic messages
  • Lightweight, compact in-line design, approximately 2.44 lb (1.11 kg) for output code S, ranges 1 to 4
  • 316L SST or Alloy C-276 wetted materials
  • Available with manifolds and remote seals

Applications

  • Gauge pressure on process lines, pumps, and utilities
  • Absolute pressure measurement down to 0 psia
  • Tank and vessel pressure with remote seal assemblies
  • Low power installations that use 1-5 Vdc HART Low Power output
  • Liquid, gas, and vapor service

Technical Specifications

  • Measurement types: gauge, absolute
  • Service: liquid, gas, and vapor applications
  • Reference accuracy: ±0.075% of calibrated span; ±0.065% of calibrated span with high accuracy option P8
  • Ambient temperature effect per 50 °F (28 °C): ±(0.15% URL + 0.15% of span)
  • Stability: ranges 2 to 5 ±0.10% of URL for three years; range 1 ±0.10% of URL for one year
  • Range 1: minimum span 0.60 psi (41.37 mbar), URL 30.00 psi (2.07 bar)
  • Range 2: minimum span 3.00 psi (206.85 mbar), URL 150.00 psi (10.34 bar)
  • Range 3: minimum span 16.00 psi (1.11 bar), URL 800.00 psi (55.16 bar)
  • Range 4: minimum span 80.00 psi (5.52 bar), URL 4000.00 psi (275.79 bar)
  • Range 5: minimum span 2000 psi (137.9 bar), URL 10000 psi (689.5 bar)
  • Lower range limit: 0 psia (0 bar) absolute; -14.70 psig (-1.01 bar) gauge
  • Output: code S 4-20 mA; code N 1-5 Vdc, Low Power; HART Revision 5 (default) or Revision 7 (option HR7)
  • Power supply: 10.5 to 42.4 Vdc with no load (5.8 to 28 V for Low Power)
  • Total response time: 145 milliseconds; update rate: 22 times per second minimum
  • Overpressure limits: range 1 120 psig max; ranges 2 to 4 two times the URL; range 5 15,000 psi (1034,2 bar)
  • Ambient temperature: -40 to 185 °F (-40 to 85 °C); with LCD display -40 to 176 °F (-40 to 80 °C)
  • Process temperature: silicone fill -40 to 250 °F (-40 to 121 °C); inert fill -22 to 250 °F (-30 to 121 °C)
  • Process connections: 1/2-14 NPT female, DIN 16288 G1/2 male, RC 1/2 female (PT 1/2 female), M20 x 1.5 (CM20) male
  • Isolating diaphragm: 316L SST (UNS S31603), Alloy C-276 (UNS N10276)
  • Electronics housing: low-copper aluminum, NEMA Type 4X, IP66, and IP68 when properly installed
  • Weight: approximately 2.44 lb (1.11 kg), output code S ranges 1 to 4; approximately 3 lb (1.4 kg), output code N or range 5
  • Hazardous locations, USA: E5 Explosion-proof and Dust-Ignitionproof (FM); I5 Intrinsically Safe and Nonincendive (FM)
  • Hazardous locations, Canada: C6 Explosion-proof, Intrinsic Safety and Division 2, Dust-Ignitionproof (CSA)
  • Warranty: one-year limited warranty standard; three-year and five-year available (options WR3, WR5)

Not every pressure point needs a coplanar transmitter with a manifold. On pump discharge lines, utility headers, and absolute pressure points, a compact in-line unit that threads straight onto the process is quicker to install and easier to support. The Rosemount 2088 is designed for that job.

The transmitter measures gauge or absolute pressure across five ranges, from a 30 psi upper range limit up to 10,000 psi (689.5 bar). Reference accuracy is ±0.075% of calibrated span, or ±0.065% with the high accuracy option, and rangeability is 50:1, so one model can cover several points in the same plant. The Local Operator Interface lets technicians commission the device at the transmitter, and the HART revision can be switched in the field.

Output is 4-20 mA HART or 1-5 Vdc HART Low Power, and the transmitter is available with manifolds and remote seals. For differential pressure, DP flow, or level, see the Rosemount 2051 and the Rosemount 3051.

The Rosemount 2088 is available through AV-TEK Consulting in North America. AV-TEK helps you choose range, process connection, wetted materials, output, and approvals for each point. Explore more electronic pressure transmitters and the full Emerson Rosemount range.

Manuals

Emerson_2088_User_Manual

Links

Spec Sheets

Emerson_2088_Datasheet

You may also like…

Professional Brands
Quality and Safety
Fast shipping
Best couriers
Check your order
In your Account
Secure Payments
Choose what you prefer

AV-TEK / Houston Office
4123 Hollister, Suite G
Houston, TX, 77080

AV-TEK / San Marcos Office
900 Barnes Dr. Suite 200
San Marcos, TX, 78666

Subscribe to AV-TEK

Receive the latest news, updates and special offers right to your inbox.
© 2026 AV-TEK
phone-handsetchevron-downcross-circle