Tunkia TD1550 - DC Energy Meters Verification Device

REQUEST PRICE
Do you need more information? Contact us
Overview
Description
Documents
Accessories
Applications

Features

  • Accuracy: class 0.02, class 0.05
  • DC standard voltage source: 10 mV ~ 1150 V / 1550 V (option)
  • DC standard current: 1 mA ~ 600 A
  • DC small-signal voltage source (four-wire): 10 μV ~ 4.4 V
  • Optional 3 or 6 meter position DC energy meter and DC shunt calibration stand
  • Auxiliary power supply DC 24 V or AC 220 V for type A electronic DC energy meters at each position
  • Clock module with precision up to 0.2 ppm and GPS receiver for daily timing error tests
  • Mobile measurement and control station with LCD touch screen; DC shunt crimping device (option)

Applications

  • Direct connected DC energy meters: 1.15 Un test of 1 kV meters and 1.2 In test of 100 A meters
  • Indirect connected DC energy meters through the four-wire small-signal source
  • Combined testing of indirect connected meters and DC shunts
  • DC shunt verification with resistance, basic error, and R(t) curve (option)
  • Calibration of DC voltmeters, ammeters, and DC watt-meters

Technical Specifications

  • DC voltage ranges 300 mV, 1 V, 3 V, 10 V, 30 V, 100 V, 300 V, 600 V, 1000 V, 1500 V (option): accuracy (k=2) 120 + 80 (Class 0.05), 60 + 40 (Class 0.02) ppm of reading + ppm of range
  • DC voltage output range: 10 mV ~ 1150 V, 6-bit display; 10 mV ~ 1550 V with the 1500 V option
  • DC current output: 1 mA ~ 600 A
  • Four-wire small-signal voltage source: ± (10 μV ~ 4.4 V)
  • DC voltage measurement up to 4.4 V; DC resistance measurement up to 200 mΩ
  • Power supply: AC (220 ± 22) V, (50 ± 2) Hz
  • Working temperature: 15 °C~30 °C; storage temperature: -20 °C ~ 70 °C
  • Working humidity: (20% ~ 50%) RH, no condensation; storage humidity: (15% ~ 80%) RH, no condensation
  • Interface: RS232

Meter labs rarely verify one DC energy meter at a time. Throughput depends on how many positions can run in parallel and how much of the sequence the software automates.

The TD1550 drives a 3 or 6 position calibration stand from DC voltage, current, and small-signal standard sources, with standard energy pulse input and output for working error. Each position has its own auxiliary supply for type A electronic meters, and the built-in clock module with GPS checks daily timing error. An optional crimping device clamps DC shunts for verification of resistance and basic error. The same sources calibrate DC voltmeters, ammeters, and watt-meters between meter runs.

For larger indirect connected batches, see the 6, 12, or 16 position Tunkia TD1570 and Tunkia TD1575; for type evaluation tests, the Tunkia TD1580. Compare models in DC power and energy standards.

AV-TEK helps you size positions, current range, and software for your meter volumes. Explore more Tunkia instruments.

Manuals

Links

Spec Sheets

Tunkia_TD1550_Datasheet

You may also like…

Professional Brands
Quality and Safety
Fast shipping
Best couriers
Check your order
In your Account
Secure Payments
Choose what you prefer

AV-TEK / Houston Office
4123 Hollister, Suite G
Houston, TX, 77080

AV-TEK / San Marcos Office
900 Barnes Dr. Suite 200
San Marcos, TX, 78666

Subscribe to AV-TEK

Receive the latest news, updates and special offers right to your inbox.
© 2026 AV-TEK