Sign in

No products in the cart.

Mo-Fr 8am 6pm CT

Tunkia TD1310 - High-Precision AC/DC Standard Meter

REQUEST PRICE
Do you need more information? Contact us
Overview
Description
Documents
Accessories
Applications

Features

  • Power/electric energy accuracy: DC class 0.01, AC class 0.02
  • Voltage/current accuracy: DC class 0.005, AC class 0.01
  • DC voltage measurement: 10 mV ~ 1150 V
  • Direct DC current measurement: 10 μA ~ 120 A; transducer extends the current range to 500 A or more
  • Small signal voltage measurement: 0.1 mV ~ 12 V
  • Full automatic range switching for all quantities
  • DC ripple and AC 2nd~63rd harmonic measurement
  • Statistics and analysis of the measured quantities; standard electric energy pulse input and output
  • Communication interface: USB, RS232, LAN

Applications

  • Assessment of AC and DC energy meter verification devices, standard energy meters, and EV charger testers
  • Verification or calibration of AC/DC voltage, current, and power sources
  • Calibration of voltmeters, ammeters, ohmmeters, power meters, power factor meters, frequency meters, phase meters, transmitters, and sensors with a test power supply
  • Shunt and I/V transformer calibration with a precision current transducer

Technical Specifications

  • DC voltage measurement range: ± (10 mV~1150 V); AC measurement range: 10 mV~800 V (valid value); manual/automatic range switching
  • DC voltage accuracy (k=2), 1 V to 1000 V ranges: 30 + 20 ppm*RD + ppm*RG
  • Input bandwidth: 50 kHz; minimum resolution: 10 nV, 8-bit display; input impedance: 1 MΩ; input protection: 1200 Vpk
  • Direct current measurement: 10 μA ~ 120 A (DC); 10 μA ~ 80 A (AC)
  • Small signal voltage: 0.1 mV ~ 12 V (DC), 2 mV ~ 10.2 V (AC); overload up to 150 Vpk
  • AC fundamental frequency: 40 Hz ~ 1 kHz; DC ripple range 1 Hz ~ 5 kHz; harmonics 2nd ~ 63rd
  • Frequency: 40.00000 Hz~1000.000 Hz, accuracy 20 ppm; phase: 0.0000°~359.9999°, accuracy 0.02° (40 Hz ≤ F ≤ 200 Hz), 0.05° (200 Hz < F ≤ 1 kHz)
  • Electric energy error display: resolution 0.001%
  • Working temperature: 15 °C~35 °C; storage temperature: -10 °C~50 °C
  • Working humidity: < 80% @ 30 °C, < 70% @ 40 °C, < 40% @ 50 °C; storage humidity: (20%~80%) RH, no condensation
  • Interface: USB, RS232, RJ45

The test benches that verify energy meters drift like any other instrument. If they are not checked against a higher-level reference, every meter they pass carries that drift into the field.

The TD1310 measures AC and DC voltage, current, power, and energy as a reference meter, with DC voltage and current accuracy of class 0.005. It handles DC, AC, and DC+AC signals, analyzing ripple from 1 Hz to 5 kHz and harmonics up to the 63rd. Small-signal inputs from 0.1 mV let it assess verification devices for indirect connected DC energy meters, and a power calculation function scales readings through dividers, shunts, and transducers.

For DC-only work with ripple bandwidth up to 10 kHz, see the Tunkia TD1300; for the highest DC energy accuracy, the Tunkia TH3000. Compare models in DC power and energy standards.

AV-TEK helps you choose the reference level for your calibration chain. Explore more Tunkia instruments.

Manuals

Links

Spec Sheets

You may also like…

Professional Brands
Quality and Safety
Fast shipping
Best couriers
Check your order
In your Account
Secure Payments
Choose what you prefer

AV-TEK / Houston Office
4123 Hollister, Suite G
Houston, TX, 77080

AV-TEK / San Marcos Office
900 Barnes Dr. Suite 200
San Marcos, TX, 78666

Subscribe to AV-TEK

Receive the latest news, updates and special offers right to your inbox.
© 2026 AV-TEK
phone-handsetchevron-downcross-circle