Sign in

No products in the cart.

Mo-Fr 8am 6pm CT

APG HU1502I - Hammer Union Pressure Transmitter

REQUEST PRICE
Do you need more information? Contact us
Overview
Description
Documents
Accessories
Applications

Features

  • Pressure ranges from 0-5,000 psi to 0-20,000 psi
  • Accuracy 0.25% of full scale (BFSL) for linearity, hysteresis, and repeatability
  • Output options: 4-20 mA (3-30 mA max) or 0-5 VDC
  • Incoloy wetted material, conforms to NACE MR-01-75 and ISO 15156-3 for sour service
  • WECO® 1502 hammer union fitting for 2 in line, no adapter required
  • Digital recalibration port for field zero and span setting
  • High shock and vibration resistance for drilling and pumping environments
  • Intrinsically safe: Class I, Division 1, Groups C and D; CSA, ATEX, IECEx, CE
  • Rated 10 million pressure cycles, frequency response under 5 ms

Applications

  • Hydraulic fracturing pressure on frac manifolds and treating iron
  • Acidizing and cementing pump discharge
  • Mud logging and measurement while drilling
  • Wellhead and standpipe pressure
  • Land-based and offshore drilling installations
  • Sour gas (H2S) service where NACE compliant wetted parts are required

Technical Specifications

  • Type: hammer union pressure transmitter, recalibratable
  • Pressure ranges: 0-5,000 psi, 0-7,500 psi, 0-10,000 psi, 0-20,000 psi
  • Accuracy: 0.25% of full scale (BFSL), linearity, hysteresis, and repeatability
  • Overpressure: smaller of 1.5 times full scale or the WECO® fitting limit
  • Burst pressure: smaller of 3 times full scale or the WECO® fitting limit
  • Temperature effects on zero and span: 0.026% FSO/°C (0.01% FSO/°F)
  • Life: 10 million cycles
  • Frequency response: less than 5 ms
  • Output at 21 °C: 4-20 mA (3-30 mA max); 0-5 VDC (110 mA inrush, 3.5 mA operating)
  • Supply voltage: 10 to 28 VDC on sensor
  • Loop resistance: 1012 ohms at 28 VDC, decreasing linearly to 0 ohms at 10 VDC
  • Insulation resistance: over 100 megaohms at 500 VAC, 70 °C
  • Shunt cal: 100% of full scale output
  • Recalibration: digital zero and span via programming unit (purchased separately, USB powered)
  • Wetted material: Incoloy, conforms to NACE MR-01-75 and ISO 15156-3
  • Housing: 316L stainless steel
  • Process connection: WECO® 1502 fitting for 2 in line
  • Operating temperature: -40 to 85 °C (-40 to 185 °F)
  • Compensated temperature: -40 to 65 °C (-40 to 150 °F)
  • Storage temperature: -50 to 120 °C (-58 to 248 °F)
  • Enclosure protection: IP67/IP65
  • Dimensions: 3.25 in (82.5 mm) and 3.38 in (85.9 mm) diameters, 3.69 in (93.7 mm) union base, 6.54 in (166.1 mm) length
  • CSA/cCSAus: Contract #237484
  • Intrinsically safe: Class I, Division 1, Groups C and D; Class I, Zone 0, AEx ia IIB T4; Ex ia IIB T4; ambient -40 to 85 °C
  • ATEX (4-20 mA): CE 0344 Ex II 1G Ex ia IIB T4 Ga (Ta = -40 °C to +85 °C)
  • IECEx (4-20 mA): Ex ia IIB T4 Ga (Ta = -40 °C to +85 °C)

Features

At the highest pressure points in well service, the process fluid is abrasive, corrosive, and pulsing, and a transmitter that drifts or fails does not just lose a reading, it puts the job at risk. The APG HU1502I is a recalibratable hammer union pressure transmitter built for exactly that duty.

It connects through a WECO® 1502 hammer union fitting to 2 inch treating iron, so it installs on frac manifolds, standpipes, and wellheads without adapters. The wetted material is Incoloy, conforming to NACE MR-01-75 and ISO 15156-3, which makes it suitable for sour service where H2S would attack standard stainless steel. Ranges run from 0-5,000 psi up to 0-20,000 psi, with a 4-20 mA or 0-5 VDC output and 0.25% of full scale accuracy (BFSL), and the transmitter is built to hold that accuracy through the shock and vibration of drilling and pumping, with a 10 million cycle rating and a frequency response under 5 ms.

The HU1502I is intrinsically safe for Class I, Division 1, Groups C and D, with CSA, ATEX, and IECEx approvals. A digital recalibration port allows field zero and span setting through a separate programming unit, and that is where AV-TEK adds value: NIST-traceable calibration and recalibration keep the transmitter inside spec across a demanding duty cycle, protecting both measurement integrity and job safety. For general industrial and hazardous area pressure, see the PT-400 and the explosion proof PT-405.

The HU1502I is available through AV-TEK Consulting in North America, with application support to select range and output, configure the unit, and support it over its service life. Explore more electronic pressure transmitters and the full APG range.

Manuals

APG_HU1502I_User_Manual

Links

Spec Sheets

APG_HU1502I_Datasheet

You may also like…

Professional Brands
Quality and Safety
Fast shipping
Best couriers
Check your order
In your Account
Secure Payments
Choose what you prefer

AV-TEK / Houston Office
4123 Hollister, Suite G
Houston, TX, 77080

AV-TEK / San Marcos Office
900 Barnes Dr. Suite 200
San Marcos, TX, 78666

Subscribe to AV-TEK

Receive the latest news, updates and special offers right to your inbox.
© 2026 AV-TEK
phone-handsetchevron-downcross-circle