AEMC MN02 - AC Current Probe

$202.00

SKU: 2129.20 Categories: ,
Do you need more information? Contact us
Overview
Description
Documents
Accessories
Applications

Features

  • Nominal range 100 Aac; measurement range 50 mA to 100 A (1 ohm load), 50 mA to 90 A (10 ohm load)
  • Output 1 mA/A, transformation ratio 1000:1 (100 mAac at 100 A)
  • Accuracy 1 percent of reading plus 0.02 A at 1 ohm load; 1.5 percent plus 0.01 A at 10 ohm load
  • Frequency range 48 Hz to 10 kHz; phase shift below 3 degrees at 1 ohm load
  • Jaw opening for conductors up to 0.39 in (10 mm); clothes-pin form for tight panels
  • 5 ft (1.5 m) lead with two 4 mm safety banana plugs
  • Safety IEC 61010-2-32: 300 V CAT IV, 600 V CAT III, Pollution Degree 2; IP40
  • AC measurement only; Type A sensor, application on hazardous live conductors permitted

Applications

  • Spot AC current checks in breaker and control panels where a full clamp meter will not fit
  • Extending DMMs, recorders, and data loggers to clamp-on AC current measurement
  • Low-power secondary transformer and industrial circuit measurement
  • Electrical maintenance and contracting on circuits rated up to 600 V CAT III

Technical Specifications

  • Type: AC current probe (clamp), Type A sensor
  • Nominal range: 100 Aac
  • Measurement range: 50 mA to 100 A (1 ohm load); 50 mA to 90 A (10 ohm load)
  • Transformation ratio: 1000:1
  • Output signal: 1 mA/A from 1 to 10 ohm load
  • Accuracy: 1 percent reading plus 0.02 A (1 ohm load); 1.5 percent reading plus 0.01 A (10 ohm load)
  • Phase shift: below 3 degrees (1 ohm load); below 6 degrees (10 ohm load)
  • Frequency range: 48 Hz to 10 kHz
  • Overload: 170 A for 10 min ON, 30 min OFF
  • Open secondary voltage: 30 V or less; working and common mode voltage: 600 VRMS
  • Output termination: 5 ft (1.5 m) lead, two 4 mm safety banana plugs
  • Maximum conductor size: 0.39 in (10 mm) diameter
  • Dimensions: 4.43 x 1.48 x 1.02 in (112.5 x 37.5 x 26 mm); weight: 6.35 oz (180 g)
  • Material: polycarbonate UL 94 V2
  • Operating temperature: 14 to 122 F (-10 to 50 C); storage: -40 to 176 F (-40 to 80 C)
  • Operating humidity: 0 to 85 percent RH
  • Safety: IEC 61010-2-32, 300 V CAT IV, 600 V CAT III, Pollution Degree 2
  • Ingress protection: IP40
  • Compatibility: AC ammeter, multimeter, recorder, or logger with input impedance under 10 ohms; for rated accuracy use a meter accurate to 0.75 percent or better
  • Replaces: Model MN185 (Cat. #100.185)

The AEMC MN02 is a small AC current probe that extends the reach of instruments you already own. Clamp it around a single conductor and connect the 5 ft lead with 4 mm safety banana plugs to any AC ammeter, multimeter, recorder, or data logger with an input impedance under 10 ohms, and you read AC current directly. The MN02 covers 50 mA to 100 A with a 1000:1 transformation ratio and a 1 mA/A output, with accuracy of 1 percent of reading at a 1 ohm load. Its frequency range of 48 Hz to 10 kHz captures both line frequency and higher-order content.

The clothes-pin jaw opens around conductors up to 0.39 in (10 mm), which is what makes the MN02 useful where a full clamp meter will not fit: breaker panels, control cabinets, and outlet wiring in low-power secondary or industrial circuits. To meet its rated accuracy, pair it with a meter accurate to 0.75 percent or better.

The MN02 is an AC-only sensor and does not measure DC. It replaces the discontinued Model MN185, so existing MN185 procedures carry over.

Manuals

AEMC MN02_User-manual

Links

Spec Sheets

AEMC MN02_Datasheet

You may also like…

Professional Brands
Quality and Safety
Fast shipping
Best couriers
Check your order
In your Account
Secure Payments
Choose what you prefer

AV-TEK / Houston Office
4123 Hollister, Suite G
Houston, TX, 77080

AV-TEK / San Marcos Office
900 Barnes Dr. Suite 200
San Marcos, TX, 78666

Subscribe to AV-TEK

Receive the latest news, updates and special offers right to your inbox.
© 2026 AV-TEK
phone-handsetchevron-downcross-circle