Sign in

No products in the cart.

Mo-Fr 8am 6pm CT

Additel 673 - Digital Pressure Calibrator

Price range: $3,529.00 through $8,462.00

Do you need more information? Contact us
Overview
Description
Documents
Accessories
Applications

Features

  • Pressure ranges up to 60,000 psi (4,200 bar)
  • 0.02%, 0.05%FS or 0.1%RD accuracy
  • Every model measures gauge or absolute pressure, with a built-in barometer (55 Pa)
  • Measures mA or V, with 24 V loop power
  • Full HART field communicator (optional)
  • Switch testing: mechanical switches and NPN/PNP digital switches
  • 3.4 inch color touchscreen with a replaceable tempered glass screen protector
  • Bluetooth and USB communication; Wi-Fi or RS232 optional
  • Data logging: 8GB (100M+ records)
  • IP67 rated, 304 SS case; CE, UKCA compliance

Applications

  • Field calibration of pressure transmitters, with loop power and mA measurement in one instrument
  • HART transmitter configuration and trim with the optional HART communicator
  • Pressure switch testing, mechanical or electronic
  • Gauge, absolute, and barometric pressure reference work
  • Logged pressure tests in the field or the lab

Technical Specifications

  • Accuracy: 673-02: 0.02% of full span; 673-05: 0.05% of full span
  • Accuracy, 673-RD: 0% to 20% of range: 0.02% of full span; 20% to 110% of range: 0.1% of reading
  • Built-in barometer: 55 Pa
  • Gauge types: gauge pressure, compound pressure, absolute pressure, differential pressure and barometric pressure
  • Pressure ranges: gauge up to 60,000 psi (4,200 bar); barometric 60 kPa to 110 kPa
  • Electrical measurement accuracy (8 °C to 38 °C): voltage DC ±30.0000 V, ± (0.01%RD + 1.5 mV); current DC ±30.0000 mA, ± (0.01%RD + 1.5 μA)
  • Loop power: DC 24 V, 24 V ±1 V, max 30 mA
  • Switch: status OPEN/CLOSED, mechanical switches and NPN/PNP digital switches (trigger voltage 2.7V)
  • Display: color touchscreen (capacitive), tempered glass screen protector (replaceable); resolution 4, 5 or 6 digits (user selectable)
  • Display rate: 3 readings per second (default), adjustable from 10 readings per second to 1 reading every 20 seconds
  • Pressure units: Pa, kPa, MPa, psi, bar, mbar, kgf/cm2, inH2O@4°C, mmH2O@4°C, inHg@0°C, mmHg@0°C and 5 customizable units
  • Compensated and operating temperature: 14°F to 122°F (-10°C to 50°C); storage: -4°F to 158°F (-30°C to 70°C)
  • Humidity: 0 to 95%, non-condensing
  • Pressure port: < 15,000 psi: 1/4NPT male, 1/2NPT male, 1/4BSP male, 1/2BSP male, M20×1.5 male; ≥15,000 psi: 1/4HP female (Autoclave F-250-C) or 1/4HP male (Autoclave M-250-C); differential pressure: barb fitting
  • Over pressure warning: 120%
  • Power: rechargeable Li-ion battery, 16 hours typical life, 4 hours typical recharge; external power 110V/220V power adapter (5 VDC)
  • Enclosure: case material 304 SS; wetted parts 316 SS
  • Size: 4.65" x 1.77" x 6.89" (118 x 42 x 175 mm); weight: 1.58 lbs (0.715 kg)
  • Data logging: 8GB (100M+ records), manual and automatic mode, interval 0.1 to 9999.9 seconds
  • Protection level: IP67; vibration: 5 g (10-500 Hz); shock resistance: 8 g/11 ms
  • Compliance: CE, UKCA
  • Communication: USB Type-C and Bluetooth included; RS232 or Wi-Fi optional
  • Accessories included: rubber boot, test leads (1 set), rechargeable Li-ion battery, USB cable (type-C), power adapter, silicone tubes (DP models only)
  • Warranty: 1 year

Calibrating a pressure transmitter in the field usually takes a pressure reference, a meter for the output, a loop supply, and often a HART communicator. The Additel 673 combines them in one handheld instrument with a 3.4 inch color touchscreen and a smartphone-style menu.

Its pressure sensor covers ranges up to 60,000 psi (4,200 bar) with 0.02% or 0.05% of full span accuracy, or 0.1% of reading with the RD version, and a built-in barometer lets every model read gauge or absolute pressure. The electrical side measures ±30 mA and ±30 V at ± (0.01%RD + 1.5 μA) and ± (0.01%RD + 1.5 mV), supplies 24 V loop power, and tests mechanical or NPN/PNP switches. The optional HART field communicator supports full HART protocols for transmitter work. Data logging stores more than 100 million records, and the IP67 case is built for the field.

ACal 9530 runs automated calibration with asset management, and LogII 9502 logs and graphs data in real time. For pressure measurement without the electrical functions, see the Additel 686.

AV-TEK Consulting supplies Additel pressure calibration equipment across North America and helps you choose the range, accuracy, and options for your work. Browse all digital pressure calibrators and gauges or the full Additel range.

Manuals

ADT673_User_Manual

Links

Additel 673 Advanced Digital Pressure Calibrators - Intro
Additel 673 Advanced Digital Pressure Calibrator - Video

Spec Sheets

Additel_ADT673_Datasheet

You may also like…

Professional Brands
Quality and Safety
Fast shipping
Best couriers
Check your order
In your Account
Secure Payments
Choose what you prefer

AV-TEK / Houston Office
4123 Hollister, Suite G
Houston, TX, 77080

AV-TEK / San Marcos Office
900 Barnes Dr. Suite 200
San Marcos, TX, 78666

Subscribe to AV-TEK

Receive the latest news, updates and special offers right to your inbox.
© 2026 AV-TEK
phone-handsetchevron-downcross-circle