Additel 783 - Pressure Controller

Price range: $8,080.00 through $12,095.00

Do you need more information? Contact us
Overview
Description
Documents
Accessories
Applications

Features

  • Pressure ranges from -14.35 psi (-0.99 bar) to 6000 psi (420 bar) across four base units
  • Two removable ADT151 pressure modules with dual-range calibration, installed or replaced in 30 seconds or less
  • 0.02%FS, 0.01%FS, and 0.01%RD accuracy
  • Control stability < 0.003%FS, typically 0.001%FS
  • 20% pressure step within 10 seconds (typical control response time)
  • Gauge and absolute pressure with the optional barometric module
  • LAN, USB, and RS232 communication with an SCPI command set
  • 7-inch color touch screen with an icon-driven interface
  • Automated vacuum pump control, volt-free contacts, and I/O alarm
  • ISO 17025 accredited calibration certificate included

Applications

  • Automated calibration of pressure gauges, transmitters, and switches on production and test lines
  • Calibration laboratories with high volume pneumatic pressure work
  • Differential and low pressure calibration with the ADT783-D
  • Pressure transmitter calibration with the optional 9065 precision electrical measurement module
  • Pressure switch testing through the dedicated switch test port

Technical Specifications

  • Max pressure range: 35 psi (2.5 bar) ADT783-D; 1000 psi (70 bar) ADT783-1K; 3600 psi (250 bar) ADT783-3.6K; 6000 psi (420 bar) ADT783-6K
  • Min pressure range: -14.35 psi (-0.99 bar), based on an atmospheric pressure of 1 bar
  • Accuracy (k=2): 0.02%FS or 0.01%FS ADT783-D; 0.02%FS or 0.01%FS or 0.01%RD ADT783-1K, 3.6K, 6K
  • Control stability: < 0.003%FS, typically 0.001%FS
  • Control response time: < 10 seconds ADT783-D, 1K, 3.6K; ≤ 20 seconds ADT783-6K
  • Pressure type: differential ADT783-D; gauge ADT783-1K, 3.6K, 6K; gauge and absolute switchable with the optional barometric module
  • Interchangeable pressure module bays: 2, plus one barometric module bay
  • Maximum high-low range ratio: 20:1 ADT783-1K; 40:1 ADT783-6K
  • Range switching mode: fixed or auto
  • Supply source: external air source (clean and dry nitrogen or air)
  • Maximum supply pressure: 4 bar ADT783-D; 80 bar ADT783-1K; 280 bar ADT783-3.6K; 440 bar ADT783-6K
  • Control mode: fast, standard, custom
  • Maximum overshoot: < 1%FS
  • Maximum load volume: 1000 mL
  • Contamination Prevention System (CPS): optional
  • Pressure port: 1/4 BSP M; all pressure ports fitted with 40 to 100 μm filters
  • Display: 7-inch capacitive touch screen, 1280 x 800 resolution
  • Communications: RS232, USB-A x2, LAN; WiFi, Bluetooth, and GPIB can be added through the USB port
  • External drive valve port: 3 channels, 24 V / 12 W maximum; one channel for the CPS, two for an external vacuum pump and isolation valve
  • I/O alarm port: 3-channel volt-free NO/NC relay, 24 V / 0.5 A
  • Pressure switch test port: mechanical and electronic switch testing
  • Power supply: AC 100 to 240 V, 50/60 Hz; maximum power consumption 150W
  • Chassis size: 17.32 x 5.23 x 14.96 in (440 W x 133 H x 380 D mm); 3U 19" rack mount
  • Chassis weight: 16.9 kg; pressure module weight: 0.5 kg
  • Operating temperature: 10°C to 50°C; storage temperature: -20°C to 70°C
  • Operating humidity: 5%RH to 95%RH, non-condensing; IP20, indoor use only
  • Conformity: CE
  • Warranty: 1 year

Model List

  • ADT783-D: differential and gauge pressure calibration from ±10 inH2O (±25 mbar) up to 36 psi (2.5 bar); ADT151 DP20 to DP1K modules
  • ADT783-1K: gauge pressure calibration from -14.35 psi (-0.99 bar) up to 1000 psi (70 bar); ADT151 CP15 to CP1K modules in the low pressure bay, CP100 to CP1K in the high pressure bay
  • ADT783-3.6K: gauge pressure calibration up to 3600 psi (250 bar); ADT151 CP150 to CP3.6K in the low pressure bay, CP2K to CP3.6K in the high pressure bay
  • ADT783-6K: gauge pressure calibration up to 6000 psi (420 bar); ADT151 CP150 to CP6K in the low pressure bay, CP2K to CP6K in the high pressure bay
  • Barometric modules (optional): ADT151-BP (±22 Pa) or ADT151-BPH (±10 Pa)

On a production line or a busy calibration bench, the pressure controller sets the pace. Waiting for each point to settle, or swapping out a whole instrument to change range, adds up across hundreds of devices. The Additel 783 is optimized for speed without giving up accuracy: a typical 20% pressure step settles within 10 seconds, with control stability below 0.003%FS.

Four base units cover differential pressure with the ADT783-D and gauge pressure up to 1000, 3600, or 6000 psi. Each takes two Additel 151 dual-range pressure modules, installed or replaced in 30 seconds or less: opening the cabin door releases pressure automatically for safe removal. An optional barometric module adds absolute pressure, and an external Additel 161 module can be used to check or calibrate the internal modules on site.

For automated systems, the 783 offers RS232, USB, and LAN with an SCPI command set compatible with common controllers, three external valve channels, volt-free alarm contacts, and automated control of an external vacuum pump. The 108-KIT contamination prevention system protects the controller from process contamination, and ACal 9530 software runs calibration routines automatically. For low pressure work with a built-in pump, see the Additel 773; for hydraulic pressure, the Additel 793.

AV-TEK Consulting supplies Additel pressure calibration equipment across North America and helps you choose the base unit and modules for your workload. Browse all pressure controllers or the full Additel range.

Manuals

Additel 773 783 793_User Manual

Links

Additel High Speed Pressure Controllers - Intro
Additel High Speed Pressure Controllers - Features and Overview
Contamination Prevention System For Additel Pressure Controllers

Spec Sheets

Additel_ADT783_Datasheet
Additel 773 783 793_Quick Star Guide
Additel_ADT151_Datasheet
Professional Brands
Quality and Safety
Fast shipping
Best couriers
Check your order
In your Account
Secure Payments
Choose what you prefer

AV-TEK / Houston Office
4123 Hollister, Suite G
Houston, TX, 77080

AV-TEK / San Marcos Office
900 Barnes Dr. Suite 200
San Marcos, TX, 78666

Subscribe to AV-TEK

Receive the latest news, updates and special offers right to your inbox.
© 2026 AV-TEK
phone-handsetchevron-downcross-circle