  • Sources, simulates, and measures pressure, temperature, and electrical signals
  • Electrical accuracy of 0.015% RD + 0.005% FS
  • High static differential pressure measurement to 0.002% FS
  • Built-in barometer
  • Dual channel pressure module ports for two external modules
  • High voltage measurement capability (300V AC) with true RMS (non-Ex)
  • Smartphone-like color touchscreen
  • USB Type-C and Bluetooth communications
  • IP67 rated, 1 meter drop test
  • Intrinsically safe 226Ex models: ATEX and IECEx, Ex ia IIC T4 Ga
  • ISO 17025 accredited calibration with data included; 3 year warranty

Applications

  • Field calibration of pressure, temperature, and mA transmitters
  • Differential pressure calibration at high static pressure
  • Pressure leak tests and safety valve tests
  • Calibration work in potentially explosive areas such as oil and gas platforms, refineries, and chemical plants with the Ex version

Technical Specifications

  • Voltage DC source: -150 to 150 mV, 0.015%RDG + 15 uV; -15 to 15 V, 0.015%RDG + 1.5 mV (non-Ex); 0 to 10.5 V, 0.02%RDG + 0.5 mV (Ex)
  • Current DC source: 0 to 25 mA, 0.015%RDG + 1.2 uA (non-Ex); 0.02%RDG + 1.2 uA (Ex)
  • Resistance source: 0 to 400 Ω, 0.015%RDG + 20 mΩ (non-Ex); 0.02%RDG + 20 mΩ (Ex)
  • Frequency source (square wave): 0.01 Hz to 50000 Hz, 0.005%RDG
  • Voltage mV (TC) source: -10 to 75 mV, 0.015%RDG + 4.0 uV (non-Ex); 0.02%RDG + 4.0 uV (Ex)
  • Loop power: 24 V ±1 V, max load current 30mA (non-Ex); 22 V ± 10%, max load current 25mA (Ex)
  • AC voltage measurement: -300 to 300 V, 0.05% RDG + 30 mV, IEC61010 300V CATII (non-Ex)
  • Operating temperature: -10°C to 50°C (226); -20°C to 50°C (226Ex)
  • Specification guaranteed temperature range: 10°C to 30°C (226); -10°C to 50°C (226Ex)
  • Storage temperature: -30°C to 70°C; humidity: <95%, non-condensing
  • Power supply: 6600mAh, 23.8Wh lithium battery (226); 4000mAh 14.4Wh explosion-proof lithium battery pack (226Ex); charging time about 6 hours, battery pack can be charged independently
  • Battery life: typically 12 hours (226); typically 35 hours (226Ex)
  • Display: 5.0 inch 480 x 800 TFT LCD capacitive screen (226); 4.4 inch 640 x 480 color display capacitive screen (226Ex); replaceable tempered glass screen protector
  • External pressure module: dual channel serial plug, can connect two digital pressure modules
  • Barometric accuracy (built-in barometer): 55Pa
  • Electrical connection: Ø4mm sockets and flat mini-jack thermocouple socket
  • Size: 6.97" x 4.13" x 2.04" (177 mm x 105 mm x 52 mm)
  • Weight: 1.6 lb (0.7 kg) (226); 1.65 lb (0.75 kg) (226Ex)
  • IP protection level: IP67, 1 meter drop test
  • Communication: isolated USB Type-C (slave), Bluetooth BLE
  • Maximum altitude: 3000 meters
  • European compliance: CE Mark
  • Calibration: ISO 17025 accredited calibration with data
  • Warranty: 3 years

Process technicians carry a calibrator to source mA, read RTDs and thermocouples, measure pressure, and power the loop, often in tight spaces and bad weather. The Additel 226 does all of it from one handheld unit with a smartphone-like touchscreen, a built-in barometer, and an IP67 rating with a 1 meter drop test.

Electrical accuracy reaches 0.015% RD + 0.005% FS, thermocouple measurement benefits from improved cold junction compensation, and two pressure module ports take external Additel 161 pressure modules. With two sensors, the high static differential pressure mode measures DP to 0.002% FS at high static pressure, and onboard apps cover leak tests, safety valve tests, and analog transmitter calibration. The non-Ex version measures up to 300V AC with true RMS. For hazardous areas, the 226Ex is certified ATEX and IECEx, Ex ia IIC T4 Ga, with up to 35 hours of battery life.

Add the Additel 129 differential pressure manifold for DP work at high static pressure, the 9080 thermocouple cable kit for thermocouples, and ACal 9530 for calibration management. For documenting and HART, see the Additel 227.

AV-TEK Consulting supplies Additel process calibration equipment across North America and helps you choose the calibrator, modules, and options for your work. Browse all multifunction process calibrators or the full Additel range.

Manuals

ADT226_User_Manual

Links

Additel 226/227 Multi-functional Documenting Process Calibrator - Intro

Spec Sheets

Additel_ADT226_Datasheet

You may also like…

Professional Brands
Quality and Safety
Fast shipping
Best couriers
Check your order
In your Account
Secure Payments
Choose what you prefer

AV-TEK / Houston Office
4123 Hollister, Suite G
Houston, TX, 77080

AV-TEK / San Marcos Office
900 Barnes Dr. Suite 200
San Marcos, TX, 78666

Subscribe to AV-TEK

Receive the latest news, updates and special offers right to your inbox.
© 2026 AV-TEK
phone-handsetchevron-downcross-circle